Previous (more recent) messageNext (less recent) messagePrevious (more recent) in topicNext (less recent) in topicPrevious (more recent) by same authorNext (less recent) by same authorPrevious page (October 1997)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Tue, 21 Oct 1997 23:11:09 UT
Reply-To:     Tom Brunson <TABRUN@CLASSIC.MSN.COM>
Sender:       Vanagon mailing list <Vanagon@Gerry.SDSC.EDU>
From:         Tom Brunson <TABRUN@CLASSIC.MSN.COM>
Subject:      Re: Propane Problems! Proxy heater warning!
Comments: To: Eric Zeno <vw4x4@FYI.NET>

Right - NEVER turn a cylinder upside down. This allows liquid propane to go to the pressure regulator, which can't maintain the required burner pressure properly on liquid. In tests the results are very unpredictable - the system may seem to work fine, then suddenly produce high pressure and / or vent gas from the regulator relief valve.

Propane is stored as a liquid under high pressure (~150 psig but varies greatly with temperature) and vaporizes as propane vapor (gas) is drawn off through the valve/regulator. The regulator reduces the pressure to about 11 in-wc (less than 1/2 psig). When the liquid vaporizes it absorbs a lot of heat - so the tanks will often "sweat" or frost around the liquid area from moisture in the air condensing on the colder tank.

If liquid reaches the regulator it flashes to vapor as it passes through, expanding and cooling greatly. A "gas" regulator is not designed to handle this, and the outlet pressure will surge around. The pressure may go high enough to open the regulator's pressure relief valve (which they are required to have), thus venting propane through the regulator vent. (This venting is a designed safety feature, since by code the regulator is supposed to be outside where it's safer to vent gas than allow high pressure into the piping.) The vaporizing liquid will also COOL the regulator - possibly to -40 and it may frost up and freeze the mechanism, thus losing pressure control. It's also possible with continued use for the piping from the regulator to the burner to cool enough that liquid propane at low pressure can flow all the way to the burner, where the heat will vaporize it fast and then the pressure may......

The possibility of liquid sloshing to a regulator on RVs is one reason the codes changed to require 2-stage regulators on them instead of single-stage "grill" regulators - the 2-stage has higher tolerance for momentary liquid. Keep this in mind if replacing a Winne regulator.

Propane, like gasoline, represents a LOT of stored energy in a small space (that's what makes it useful) - and mis-using it can release that energy in very destructive ways.

Sorry for the lecture - I spent years on the National Propane (then LP-GAS) Association Safety Committee, and saw too many results of mis-using the equipment and fuel.

Tom Austin, TX

---------- From: Vanagon mailing list on behalf of Eric Zeno Sent: Tuesday, October 21, 1997 7:03 AM To: Vanagon@GERRY.SDSC.EDU Subject: Propane Problems! Proxy heater warning!

This happened last year.

A friend a mine heats his garage with a 20 lb. propane tank and a construction sight, style heater. (looks like a karosone). Some other people who rent one of the adjacent garages, liked this heater and bought one. As we were talking over the holiday, the tank was running low on propane, so my friend walked over to it, and turned it upside down. He said he did this to ensure the tank would completely empty. I didn't like the idea, but if it was almost empty, not much could happen. Well the people with the adjacent garage saw this, and inverted there brand new full tank of propane. After sometime THE GARAGE BURST INTO FLAMES! For some reason, up at the tank end, something failed, the regulator or maybe the hose burst. This sent propane across there garage and flamed up, instantly, as it got near the heater.

3 Fire companies were called to put out the fire. Later It was found that the hose had burst. I don't no if this was a resault of inverting the tank or not. The hole thing was brand new, so the problem wasn't wear. Anyone have any ideas on this? I'm thinking that inverting the tank forced liquid out of the hose, maybe causing an over pressure. If this is true could driving with a proxy heater turned on cause the same problem?

Eric 86-VW4x4 vw4x4@fyi.net 72-240z Pittsburgh, PA USA 1936-Chrysler


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.