When our daughter was born I became concerned that that I was either freezing her or cooking her in the back of the camper. I added a line thermostat model 4E036 less than $20.00, that I bought through Grainger, to control the blower. I interrupted the ground to the blower motor using standard 1/4 spade connectors, this way all three speeds are controlled, and it's easily returned to it's original setup. I just set the temp on the stat, set the blower speed on the dash and I don't have to worry. It cycles on and off just like home. I mounted the thermostat next to the "clothes closet" with velcro, so I can remove it easily during the summer. There are other thermostats that could be used, I just picked the least expensive. Hope this helps someone. Good luck. Doug '86 GL Westy Maryland |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.