Date:         Thu, 12 Nov 1998 13:01:56 EST
Reply-To:     David Beierl <dbeierl@IBM.NET>
Sender:       Vanagon Mailing List <vanagon@vanagon.com>
From:         David Beierl <dbeierl@IBM.NET>
Subject:      LP tank / Plat Cat
Comments: To: Robyn Rudisill <robyn.rudisill@HOME.COM>, vanagon@VANAGON.COM

** Reply to message from Robyn Rudisill <robyn.rudisill@HOME.COM> on Thu, 12 Nov 1998 11:34:06 -0600

> What is the capacity of a 1991 Westy LP Tank? With that auto shut off > valve it seems I can only get about a gallon and a half into that tank > before the pump quits. Is that normal?

As far as I know it's the same as the '84 -- 10 lb or 3 gallons. I get 2.8 in mine. In order to get proper fill the van has to be level in both directions, since the shutoff is triggered by liquid propane flowing through the bleed tube. The tube is well aft of the center of the tank -- when my van was in Scotland (most of its life) the only LP supplier within 100 miles was a taxi company and their driveway was at a steep grade -- never got more than a gallon into the tank.

Re someone's question about running time for the Plat Cat -- I did some numbers awhile ago and found that you could run one stove burner (5200 BTU/hr) for 48 hours straight on a full tank. Therefore the total running time for a 6000+ BTU/hr Plat Cat would be less than 48 hours. I'd plan on bringing a BBQ tank, myself. > > Interestingly enough, the rv/propane guy said that when they get complaints > about these valves, their "fix" is to remove them. His comment was along > the lines of, "any moron should be able to see propane coming out of a > bleeder valve and know that full is full."

I wish that someone would inform the NFPA -- as of today any LP tank manufactured btw 4 and 40 lb must have an *internal, float-type* shutoff *in addition to* the bleed valve. As of January 2002 it will be illegal to fill any such tank that does not. The Westy autoshutoff valve does *not* qualify. I'm trying to find out whether ASME tanks like ours have this requirement, but I fear they do.... >

david

David Beierl <dbeierl@ibm.net> 401 274-5827 voice, -6349 fax OS/2 V4, FP7, JVM 1.1.6, JSM 98.6.3


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.