Date:         Fri, 14 May 1999 15:03:17 -0400
Reply-To:     David Beierl <synergx@IBM.NET>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         David Beierl <synergx@IBM.NET>
Subject:      Re: Source for water tank level sensor
In-Reply-To:  <012b01be9e33$0739c5e0$6f6f6f6f@aptiva>
Content-Type: text/plain; charset="us-ascii"; format=flowed

> > move the float all the way down to within one inch of the bottom, > > then I get another click and the Ohm meter goes to 350K (nearly > > infinity - open circuit). If that is of any help to anybody

In this context, 350k is far from an open circuit. The sender is fed 12v through a one-megohm resistor, at least on the earlier arrangement -- and the evidence to date indicates that they didn't change the LED panel for the new sender. The LED panel senses voltage and has an input impedance that could easily be ten megohms. In stock form it should light green if it sees btw 0 and 3 volts, Yellow from 3 to 5, Red from 5 to 7, and no lights above 7 volts. Again, I'm speaking of the '84 version and we have not yet established for certain that the later ones are identical. Occam thinks they are, though.

david David Beierl - dbeierl@ibm.net


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.