Hi Steve, The most trouble some is the one under and to the front of the coil that has a ground strap that goes over to the left head. This is a critical ground on both ends for the digifant 86 -91. the one inside next to the ecu rarely gives problems. On a digijet (83.5-85), be sure your ecu is good and tight in the mounting frame and the frame is attached well to the van body. The grounds to the body in front of the coil are important also. Darrell ----- Original Message ----- From: Steven X. Schwenk <Steve@Schwenk-Law.com> To: <vanagon@GERRY.VANAGON.COM> Sent: Thursday, June 17, 1999 9:22 PM Subject: Send in the Grounds...
> Where are the main ground connections that if loose may > affect FI performance? > I need a little help due to time. > Thanks > steve > |
Please note - During the past 17 years of operation, several gigabytes of
Vanagon mail messages have been archived. Searching the entire collection
will take up to five minutes to complete. Please be patient!
Return to the archives @ gerry.vanagon.com
The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.