Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (October 1998, week 2)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Sat, 10 Oct 1998 16:42:12 -0700
Reply-To:     KBatzler <KBatzler@EMAIL.MSN.COM>
Sender:       Vanagon Mailing List <Vanagon@vanagon.com>
From:         KBatzler <KBatzler@EMAIL.MSN.COM>
Subject:      84 Vanagon A/C
Comments: To: Vanagon <Vanagon@VANAGON.COM>
Content-Type: multipart/alternative;

Hi to all those on the list, I just signed up last week and I'm just thrilled about all the info you folks supply. Many thanks in advance. I own an 84 Vanagon 4 sp w/ A/C. Thanks to Gregory Ramirez for the info about the radiator fan coming on automatically with the ignition (when the evap fan switch is on). My question of the day (and I will have many soon) is when I am using my a/c on a very hot day (we get many days over 115F for three months), the compressor clutch comes on with the thermostat. but when the raditor fan goes into high speed, it cuts out the compressor until the low speed resumes again. This can be very frustrating as the inside of the van will reach 100F in no time flat! I can find ab- solutely no pressure switches anywhere to cause the compressor to cut out. Is this normal to prevent the motor from overheating? I've checked the relays (under the dash) and they seem to be fine. Is there anyother things that I should be checking? Appreciate any advice you folks may have. Thanks, Karl Batzler KBatzler@msn.com


[text/html]


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.