Vanagon EuroVan
Previous messageNext messagePrevious in topicNext in topicPrevious by same authorNext by same authorPrevious page (June 2005, week 2)Back to main VANAGON pageJoin or leave VANAGON (or change settings)ReplyPost a new messageSearchProportional fontNon-proportional font
Date:         Mon, 13 Jun 2005 11:05:14 -0400
Reply-To:     David Bohannan <fjazzbass@GMAIL.COM>
Sender:       Vanagon Mailing List <vanagon@gerry.vanagon.com>
From:         David Bohannan <fjazzbass@GMAIL.COM>
Subject:      Re: 85 AC problems...pressure too high with small amount of
              refrigerant
In-Reply-To:  <001501c56d43$e62b4900$6400a8c0@masterpc>
Content-Type: text/plain; charset=ISO-8859-1

I think the problem was too little oil...

Drained and vacuumed the system, added an "oil charge" can plus 134 and it workee workee...low pressure on low side, high pressure on high side...

At least for a couple days thus far.

Thanks to all for the advice...

Dave

On 6/9/05, Dennis Haynes <dhaynes@optonline.net> wrote: > My bet is you have a bad expansion valve. The replacement valves are > also designed for the R-134A. > > Dennis > > -----Original Message----- > From: Vanagon Mailing List [mailto:vanagon@gerry.vanagon.com] On Behalf > Of David Bohannan > Sent: Thursday, June 09, 2005 1:29 PM > To: vanagon@GERRY.VANAGON.COM > Subject: 85 AC problems...pressure too high with small amount of > refrigerant > > Weird problem...maybe someone has an idea for me... > > I have just replaced all my lines, replaced the dryer, flushed out the > system, vacuumed the system, cleaned out the expansion valve and when > charging the system after putting in a 2oz can of oil, 12 oz can of > refrigerant with dye and on the next 12 oz can no more would enter the > system....maybe we have 24 oz in total... > > The guages are reading VERY high on BOTH sides of the system...in > excess of 250 on high and well over 100 on the low...it cools, but I > am afraid I may blow up something..so I am not running it until I get > a proper diagnosis... > > One mechanic I know said that the compressor may be bad...cracked > valve? I am hoping not, but what else could be causing this problem??? > FWIW, the cooling fan comes on and is turning in the proper > direction....bad new dryer?? > > Dave > 85 gl "Baby bus" > > >


Back to: Top of message | Previous page | Main VANAGON page

Please note - During the past 17 years of operation, several gigabytes of Vanagon mail messages have been archived. Searching the entire collection will take up to five minutes to complete. Please be patient!


Return to the archives @ gerry.vanagon.com


The vanagon mailing list archives are copyright (c) 1994-2011, and may not be reproduced without the express written permission of the list administrators. Posting messages to this mailing list grants a license to the mailing list administrators to reproduce the message in a compilation, either printed or electronic. All compilations will be not-for-profit, with any excess proceeds going to the Vanagon mailing list.

Any profits from list compilations go exclusively towards the management and operation of the Vanagon mailing list and vanagon mailing list web site.